Description
The CJTZ is a concealed connector. It can be installed three ways: with no routing of header/post or beam, a routed header/post or a routed beam. It is part of a concealed connector system that includes the CPTZ and CBTZ.
Material
- 12 gauge
Finish
- ZMAX® coating
Installation
- Use all specified fasteners; see General Notes.
- The CJTZ is supplied with all dowels and screws required. Screws require a hex-head driver.
- Router end of beam for screw heads for flush installation.
- The carried member may be sloped up or down to 45° with full table loads.
Warning
- This connector requires special attention to ensure correct installation. The beam must be installed perpendicular to the support member. The connection's components may be damaged if the beam is rotated from its opposite end during or after installation. Damaged components may not be noticeable and may reduce the connector's load carrying capacity.
Options
- See technical bulletin CJTZ/HCJTZ — Concealed Joist Tie Kits (T-C-CJTZ).
Ordering Information
- The CJTZ only is available with two dowel lengths.
- To order: specify short (e.g. CJT3ZS) or long dowels (e.g. CJT3ZL).
- Short dowel (1/2" x 2 3/4") for use with 3 1/8" glulam beam, 4x sawn lumber or 3 1/2"-wide PSL. Long dowel (1/2" x 4 3/4") for use with 5 1/8" glulam beam, 6x sawn lumber or greater widths.
The HCJTZ is a concealed connector. It can be installed three ways: with no routing of header/post or beam, a routed header/post or a routed beam. It is part of a concealed connector system that includes the CPTZ and CBTZ.
The HCJTZ is a heavy concealed beam tie to be used with large glulam beams resisting heavy loads. The HCJTZ features a unique shape that allows installers to insert the connector into the end of the beam without a visible slot cut into the bottom of the beam.
Material
- 10 gauge
Finish
- ZMAX® coating
Installation
- Use all specified fasteners; see General Notes.
- The HCJTZ is supplied with all dowels and screws required. Screws require a hex-head driver.
- Router end of beam for screw heads for flush installation.
- The carried member may be sloped up or down to 45° with full table loads.
Warning
This connector requires special attention to ensure correct installation. The beam must be installed perpendicular to the support member. The connection’s components may be damaged if the beam is rotated from its opposite end during or after installation. Damaged components may not be noticeable and may reduce the connector's load carrying capacity.
Load Tables
These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.
- Center dowel in beam. Short dowel (1/2" x 2 3/4") is for use with 3 1/8" glulam beam, 4x sawn lumber, or 3 1/2" wide PSL. Long dowel (1/2" x 4 3/4") is for use with 5 1/8" glulam beam, 6x sawn lumber, or greater widths.
Load Tables
These products are available with additional corrosion protection. Additional products on this page may also be available with this option, check with Simpson Strong-Tie for details.
- Center dowel in beam. Short dowel (1/2" x 2 3/4") is for use with 3 1/8" glulam beam, 4x sawn lumber, or 3 1/2" wide PSL. Long dowel (1/2" x 4 3/4") is for use with 5 1/8" glulam beam, 6x sawn lumber, or greater widths.